May 05

Phison MPALL – 0x0027 IDBLK file Version check error

If, when using Phison’s production tool (MPALL) you encounter the following error:

IDBLK file Version check error 0x0027

this is what you have to do:

1. check your IDBLK_TIMING.dll’s version

 1

2. add your version to your configuration

2.a manually: add a “[Customize Info]” section (if you don’t already have it) and on a new line: IDBlkLibrary_Version=X.X.X.X

2a

2.b using the configuration tool

i. choose advanced setting

2b1

ii. go to “other setting” and add “[Customize Info] IDBlkLibrary_Version=1.2.16.0″ to “Special setting”

2b2

Update: Sergio Silveira recomends using a new MPALL file: Phison MPALL v3.63.0C-DL17.rar (see comment)